11290 Creeks Avenue
Dunnellon, FL 34432
(352) 489-3917

Local Reviews
for citrus springs, fl

Rated 5.0 out of 5 stars based on 4 customer reviews

Awesome Service, Best in class

I have had a completely new system put in. I could not be happier with the work, professionalism, and custom job they did on my home. Outstanding, detailed and Reasonably priced. If anyone is in need of their services I would 100% highly recommend them . Thank you Terry, Mik,e David, and William.


Response from Bowers Heat & Air, Inc.:

We thank you for sharing your positive experience. It made our day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service Call

Called in morning for service and by mid morning we were up and running.


Response from Bowers Heat & Air, Inc.:

We are pleased to know your experience with us was a good one!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Not only excellent service but honest too.


Response from Bowers Heat & Air, Inc.:

Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

We have always been very satisfied with the service, the price, and the personnel. we thank you for all of the above.


Response from Bowers Heat & Air, Inc.:

Your kind words mean a lot to us. Thanks for the positive feedback.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for citrus springs, fl

Joe P.

Joe P. Job Checkin

Today, I repaired a Carrier 24ACC6 air conditioner in Citrus Springs, FL. The unit wasn’t cooling efficiently due to a faulty capacitor. I replaced the 45/5 MFD capacitor and tested the compressor and fan motor for proper function. I also checked refrigerant levels, ensuring they were within the manufacturer’s recommended range. After repairs, I inspected the evaporator coils and cleaned them to improve cooling efficiency. The system is now functioning at peak performance, with proper airflow and cooling output. The homeowner should experience improved energy efficiency and reliable cooling for the rest of the season.


Joe P.

Joe P. Job Checkin

In Citrus Springs, FL, I installed a Honeywell F300 electronic air cleaner to improve indoor air quality. This system filters out airborne particles and allergens. After installation, I tested the system for proper operation, ensuring clean air circulation throughout the home.


Terry B.

Terry B. Job Checkin

Repaired a Goodman GSX16 HVAC unit that was not providing sufficient cooling. The issue was traced to a blocked evaporator coil. Removed the blockage and cleaned the coil using a coil cleaner. Replaced the air filter with a MERV 13 filter to improve airflow. After repairs, tested the system and confirmed it was cooling efficiently with proper airflow throughout the home.


Charles L.

Charles L. Job Checkin

Installed a zoned AC system using a Honeywell HZ432 TrueZONE panel in a two-story home. Added dampers to the existing ductwork to create separate cooling zones. Wired and connected the thermostats to the zoning panel and configured each zone for optimal cooling efficiency. Tested the system to ensure each zone was cooling independently and adjusted the dampers as needed. The zoned system is now fully operational, providing customized comfort throughout the home.


Charles L.

Charles L. Job Checkin

Installed a whole-home germicidal UV light system today. Used RGF REME HALO-LED air purification device, mounting it in the supply plenum of the existing HVAC system. Wired the unit to a dedicated 24V transformer. Secured mounting bracket with self-tapping screws. Installed the UV lamp, ensuring proper alignment with airflow. Sealed connections with silicone caulk. Tested operation using UV-resistant goggles. Completed installation in 2 hours, enhancing indoor air quality and reducing airborne pathogens.


Joe P.

Joe P. Job Checkin

Repaired Lennox XC16 air conditioner today. Diagnosed faulty compressor contactor using Fluke 116 HVAC multimeter. Replaced with new Honeywell DP2030A5004 contactor. Recharged system with R410A refrigerant using Yellowjacket 42006 manifold gauge set. Cleaned condenser coils with Nu-Calgon 4171-75 Evap Foam. Tested amperage draw with UEi DL389 clamp meter. Verified proper operation, achieving 18°F delta T across evaporator. Completed repair in 3 hours, restoring optimal cooling performance.


Charles L.

Charles L. Job Checkin

Performed cooling HVAC maintenance today. Cleaned Trane XR14 condenser coils with Nu-Calgon Evap Foam. Replaced air filter with MERV 11 pleated filter. Checked refrigerant levels using Fieldpiece SMAN460 manifold gauge set. Cleaned condensate drain line with CO2 cartridge blaster. Lubricated fan motor bearings with 3-IN-ONE motor oil. Tested capacitor with Fluke 902 FC HVAC meter. Inspected ductwork for leaks. Calibrated Honeywell T6 Pro thermostat. Maintenance completed in 2.5 hours.


Terry B.

Terry B. Job Checkin

Completed the installation of a whole-home air purification system to improve indoor air quality. Installed an Aprilaire Model 5000 electronic air cleaner, which uses advanced filtration to remove particulates, allergens, and pollutants from the air. Integrated the system with the existing HVAC unit for seamless operation. Tested the system to ensure optimal performance and explained maintenance procedures to the homeowner. This installation will significantly enhance indoor air quality, providing a healthier living environment. Regular filter changes and periodic inspections are recommended to maintain system efficiency.


Charles L.

Charles L. Job Checkin

Inspected an AC unit that was not cooling. The system, which is 20 years old, showed significant rust and wear. Checked refrigerant levels and found the compressor was failing. Due to the unit's age and condition, I provided an estimate for a new HVAC system. Recommended a Carrier Comfort Series 14 SEER packaged system for optimal performance. Advised the customer on energy savings, warranty options, and the benefits of upgrading to a modern system. Regular maintenance will extend the life and efficiency of the new installation.


Terry B.

Terry B. Job Checkin

Replaced a failed thermocouple on a Lennox G61 natural gas furnace. Shut off gas supply and removed burner assembly. Installed new Q3200U universal thermocouple properly positioned in pilot flame. Reassembled burners and restored gas service. Used combustion analyzer to verify proper fuel/air mixture. Cycled heating sequences to confirm safe ignition before leaving job site.


David C.

David C. Job Checkin

Recently, I addressed a malfunctioning compressor in an AC unit located in Citrus Springs, FL. The issue led to the system's inability to cool effectively. After diagnosing the problem, I replaced the faulty compressor and conducted a system pressure check to ensure no other underlying issues. Post-repair, I cleaned the unit's filters and adjusted the airflow for optimal performance, restoring a comfortable and cool indoor environment.


Cara B.

Cara B. Job Checkin

I conducted a repair on a Carrier Infinity 21 Central Air Conditioner. This involved diagnosing the system for faults, resulting in the replacement of a faulty capacitor (model CAP-024-250) and a worn fan motor (model FM-055). Post-replacement, I recharged the system with R-410A refrigerant to optimal levels and tested for efficient cooling and operational integrity, ensuring the unit's peak performance.


David C.

David C. Job Checkin

Just completed an AC repair job in Citrus Springs, FL. The customer's unit had a refrigerant leak, resulting in insufficient cooling. Using electronic leak detection tools, I located and repaired the damaged area before recharging the system with the appropriate refrigerant. Additionally, I cleaned the coils and ensured proper airflow. The AC is now running smoothly, maintaining a cool and comfortable home environment.


Charles L.

Charles L. Job Checkin

Conducted heating maintenance for a homeowner, ensuring the furnace operates efficiently throughout the winter. Checked and replaced filters, ensuring optimal performance.


Cara B.

Cara B. Job Checkin

Air conditioner repair: A resident reported reduced cooling efficiency. After conducting a thorough examination, I identified a refrigerant leak in the air conditioning system. I sealed the leak, recharged the refrigerant, and performed a system check to ensure optimal cooling.